Texas Commercial Kitchen 101 Get connected

Home › Guides › Restaurant hoods and exhaust in Texas

Restaurant hoods and exhaust in Texas: codes and permits

  1. Pick what you need and give your kitchen's ZIP code.
  2. Each service goes to the number of local companies you choose, from one to five. We check licenses where the law requires one and email you their names.
  3. You talk with them and decide. You hire and pay the company directly.
Get connected

Facts checked 2026-11-02.

A new stainless kitchen hood with baffle filters over a cooking line
A new hood over a cooking line.

In Texas, a commercial kitchen hood and its exhaust system are permitted and inspected at the city level. Each city adopts its own mechanical code and amendments. The permit office tells you which contractor may pull the permit and what inspections to expect.

There is no statewide mechanical permit

Texas has no single statewide fire code, and the same patchwork applies to the building trades. A city adopts a set of codes and changes them by ordinance.

CityMechanical codeFire code
Houston2021 Uniform Mechanical Code, with Houston amendments, in the 2021 Houston Construction Code effective January 1, 20242021 International Fire Code with Houston amendments
Dallas2021 International Mechanical Code (city code chapter 55) with Dallas amendments, effective May 12, 20232021 International Fire Code with Dallas amendments, effective February 10, 2023

The two cities use different mechanical codes. Do not assume a hood drawing that passed in one city will pass in another.

Roof Ceiling Exhaust fan on the roofPulls smoke and grease up and out Grease ductWelded, sealed, with cleanout doors HoodBaffle filters catch grease Grease cup at the end FryerGriddleRange Cooking line: heat, smoke and grease rise into the hood Makeup airFresh air comes back into replace what leaves Room air
How a hood system moves air: up through the filters and duct, out the roof fan, with makeup air coming back in.

What Houston asks for

Houston's Mechanical Inspections section answers code questions about commercial kitchen hoods and inspects them. A mechanical permit and inspection is needed for commercial kitchen ventilation systems, including the replacement of one. The city also lists a test it calls the PCC test for commercial kitchen ventilation.

A mechanical inspector must inspect and approve the work before the project is finalized. The contractor usually calls in the required inspections: cover, grill seal and final. The section also registers licensed HVAC contractors. Its phone number is 832-394-8850.

The fire side is separate. Houston's amended fire code says a commercial cooking fire-extinguishing system must be recognized for protecting commercial cooking equipment and its exhaust. Pre-engineered dry and wet chemical systems are tested to UL 300 and must be listed and labeled for the use. The system is installed to the code, NFPA 96, its listing and the maker's instructions.

A local company can take it from here. One form, free for restaurants.

Get connected

What Dallas asks for

Dallas adopted the 2021 International Mechanical Code and the 2021 International Plumbing Code with Dallas amendments. The Dallas fire code text says an automatic sprinkler system goes in commercial kitchen exhaust hood and duct systems where a sprinkler system is used to meet the fire-extinguishing section. Dallas Fire-Rescue's permit fee schedule has a separate line for a commercial cooking fire-extinguishing system.

Midlothian's fire marshal checklist for kitchens

Some cities publish a checklist of what an inspector looks for, and the lists differ from city to city. Midlothian's fire marshal asks for:

The state air conditioning license skips the hood itself

The Texas Department of Licensing and Regulation licenses air conditioning and refrigeration contractors. The Occupations Code says that chapter does not apply to a person who installs, repairs or removes a vent hood of the type commonly used in residential or commercial kitchens. So installing the hood itself does not fall under that state license. The exemption says nothing about ducts, fans or make-up air, which a city may treat as mechanical work. Ask the permit office which license it requires.

What the health inspector checks

The state food rules adopt the 2017 FDA Food Code. Hoods over food preparation and warewashing areas must be designed so that grease or condensation cannot drip onto food, equipment or utensils. Grease filters must be designed to be readily removable for cleaning unless they are cleaned in place.

Who does what

Texas hood and exhaust work, new or replacement, can go on the form, and one local contractor that does hood work gets the request.

Questions

Does Texas have a license for kitchen hood installers?

Not through the air conditioning and refrigeration chapter. The Occupations Code says that chapter does not apply to someone who installs, repairs or removes a kitchen vent hood. Your city's permit office says who may pull the permit.

Does a new commercial kitchen hood need a permit in Texas?

In Houston, a mechanical permit and inspection are needed for commercial kitchen ventilation systems. In other cities, ask the permit office.

Which mechanical code applies to a restaurant hood in my city?

Cities pick their own. Houston uses the Uniform Mechanical Code with amendments, and Dallas uses the International Mechanical Code with amendments.

Sources

  1. Houston Mechanical Inspections
  2. Houston code development, 2021 Houston Construction Code
  3. Houston amendments to the 2021 International Fire Code
  4. Dallas current city codes
  5. Dallas 2021 International Fire Code amendments, ordinance 23-0118
  6. Dallas Fire-Rescue schedule of permit fees
  7. Midlothian Fire Marshal's Office, fire protection inspections
  8. Occupations Code 1302.060, vent hoods
  9. FDA Food Code 2017, sections 4-202.18 and 4-204.11
  10. 25 TAC 228.1, Texas adoption of the Food Code